Herunterladen Inhalt Inhalt Diese Seite drucken

Important Instructions - Truma Saphir compact Gebrauchsanweisung, Einbauanweisung

Vorschau ausblenden Andere Handbücher für Saphir compact:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Air conditioning unit Saphir compact

Important instructions

Repairs may only be carried out by properly qualified
professionals!
1. In order to avoid transport damage, the device must not be
sent until the Truma Service Centre has been contacted.
2. The voltage must be disconnected at all poles before the
housing is opened.
3. The 230 V, T 5 A H-type (slow, IEC 127) fuse in the unit can
be found on the electronic control unit and must always be
replaced with an identical fuse.
Appliance fuses and connection leads may only be replaced by
a properly qualified person.
4. Any modifications to the device or the use of spare parts
and accessories that are important to the operation of the
system that are not original Truma parts and failure to follow
the installation and operating instructions will cancel the
warranty and indemnify Truma from any liability claims.
5. The refrigerant circuit contains R 407c refrigerant and must
only be opened by an expert in the factory.
6. The cool air outflow and the ambient air suction intake must
not on any account be obstructed. Please bear this in mind in
order to ensure the trouble-free operation of your device.
7. The apertures beneath the vehicle floor must be kept free of
dirt and snow slush. The apertures must not be located within
the area subject to spray from the wheels or mudguards.
Splash protection must be provided if necessary.
8. If the floor of the vehicle is provided with underfloor pro-
tection, all the apertures beneath the vehicle must be covered
in order to prevent the spray created from penetrating the
device and causing malfunctions. Once the work has been
completed the covers can be removed again.
9. In order to avoid damage to the compressor, when the
device is in operation during transit (for example, with the
generator or voltage transformer working), do not attempt
uphill or downhill gradients of more than 8%.
10. Do not allow cooling operation to run for extended periods
in a tilted position, since the condensation water which forms
may not be able to run off, and in the worst scenario might
penetrate into the vehicle.
11. For problem-free operation and in order to avoid damage,
the supply voltage must always come from a source with a
sine wave curve (e.g. voltage converter, generator) and without
voltage spikes.
12. When the floor of the vehicle is being cleaned, it must be
ensured that no water penetrates the openings in the base of
the unit when spraying with a high-pressure cleaner, for
example.
Notes for the use of air conditioners
– For operation while driving we recommend an alternator
with output of at least 120 Ah.
– The Saphir compact air conditioning unit is designed for
minimal power consumption. Nevertheless, you should
check before taking the system into operation whether the
camping site has adequate fuses (min. 3 A).
– As far as possible, park your vehicle in the shade.
– Darkening the interior with window blinds and/or a roof
awning will reduce the penetration of radiant heat.
– Clean the roof of the vehicle regularly (dirty roofs heat up
more readily).
– Before operating the device, ventilate your vehicle thoroughly,
in order to allow the hot air which builds up inside to escape.
– Take care when putting up awnings or similar that there are
sufficient openings for the supply air to be discharged. The
opening for the hot discharge air should not be on the intake
side.
– To create a healthy environment on the inside of the vehicle,
the difference between the inside and outside temperatures
should not be selected as too great. During operation the
circulated air will be purified and dried. Due to the drying of
the moist, humid air, a pleasant environment will be created
inside even with slight temperature differences.
– Keep the doors and windows closed while the cooling
system is in operation.
11