4.2- Checking the rotation direction:
a
>>
Press the "UP" button of the transmitter:
a. If the motorized tube runs in the up direction, go to next stage 4.3.
b. If the motorized tube runs in the down direction, reverse the rotation direction by pressing the "Stop"
button for at least 3 seconds. The motor will run for 0,5 second in one direction, then in the other direction.
Move to the stage 4.3.
4.3- Adjustment of the end-limits - memorizing the end points:
The end limits of the motor EBHz are adjusted in 4 different ways depending on the following conditions:
Bottom slat stop or not, rigid* or flexible link between the rolling shaft and the shutter.
A
*V.A.R
V.A.S
Easylink
OctoEasy
1
A
B
1
1- Move the motor to the up end limit by using the buttons "UP" or "DOWN".
2- To memorize the UP end limit position, press simultaneoulsy the buttons "STOP" and "DOWN". The
motor will run automatically in the down direction.
3- Press the "STOP" button to immobilize the motor.
4- Press 2 seconds the "STOP" button to confirm the adjustment. The motor will run for 0,5 second in one
direction, then in the other direction. Go to stage §5.
C
1
1- Move the motor to the down end limit by using the buttons "UP" or "DOWN".
2- To memorize the down end limit position, press simultaneoulsy the buttons "STOP" and "UP". The motor
will run automatically in the up direction.
3- Press the "STOP" button to immobilize the motor.
4- Press 2 seconds the "STOP" button to confirm the adjustment. The motor will run for 0,5 second in one
direction, then in the other direction. Go to stage §5.
OK
4.3
>>
>>
b
B
*V.A.R
V.A.S
Easylink
OctoEasy
1- Simultaneously press the "UP" and "DOWN" buttons
2
2s
2- Press the "Stop" button for 2 s. The motor will run for
>>
C
of the transmitter. The motor will run for 0,5 second in one
direction and then in the other.
0,5 second in one direction and then in the other. The operation
is completed. Go to stage §5.