Installation

The sauna heating unit is designed for operation with an input voltage of 400 V AC 3N through the
sauna control unit and a separate power extension unit.
Sauna heaters may be operated via remote control* only in combination with an approved safety
system like EOS switch-off cover protection rail.
*Remote control – means settings, switching, control and adjustment of the sauna control unit by means
of commands transmitted from a remote location beyond sight distance using telecommunication,
wire- or wireless signal transmission systems, network and similar systems
Minimum clearances (safety gaps)
The sauna cabin must have a minimum inner height of 210 cm.
The vertical gap between the top of the sauna heater and the inner surface of the sauna ceiling must
be at least 130 cm, the horizontal gap between the heater and the cabin wall or other flammable
materials must be at least 15 cm.
The distance between the heater guard and/or bench and other flammable materials must be at
least 10 cm. The height of the heater guard must be the same as the height of the front of the stove.
Sensor
320
min.
100
min.
150
!
By installation in the centre of the sauna or by a closed glass wall make sure to
provide the adequate air supply from below through the bottom.