Installation
The sauna heater is intended for power supply 400 V 3N AC.
Identifikation:
G 18 = 18 kW
G 24 = 24 kW
G 30 = 30 kW
G 36 = 36 kW
Width = 96 cm
Minimum clearances
The sauna cabin must have a minimum inside height of 2.10 m.
When installing the sauna heater ensure that the vertical safety gap between the top surface of the
sauna heater body and the roof of the sauna is at least 127 cm, and that the horizontal safety gap
between the heater and the cabin wall or other flammable materials is at least 8 cm.
The distance between the heater guard rail and/or bench and other flammable materials must be at
least 8 cm. The height of the heater guard must be the same as the height of the front of the stove.
~85 cm
~50 cm
49 cm
8 cm
40 cm
96 cm
8 cm
Zuluft
Positioning of temperature sensor
Contradictory to the specifications concerning the mounting of the sensor of your sauna control
unit, the heater sensor shall not be mounted across the centre above the sauna heater but, as
shown in the diagram.
30
EN