Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Dimensions - Truma S 2200 Einbauanweisung

Vorschau ausblenden Andere Handbücher für S 2200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

Technical data

(determined in accordance with EN 624 or Truma test conditions)
Gas type
Liquefied gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Rated heat output
1850 W
Gas consumption
50 – 170 g/h
Additional information in accordance with EN 624
Q
= 2.4 kW (Hs); 178 g/h; C
; I
n
51
3B/P(30)
Destination countries
AT, BE, BG, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HR,
HU, IE, IS, IT, LI, LT, LU, LV, MT, NL, NO, PL, PT, RO, SE, SI,
SK, TR
Operating voltage
1.5 V (auto ignitor with battery operation)
Power consumption
225 mW (ignition)
Weight
approx. 6.7 kg
Subject to technical changes.

Dimensions

AKW 2 = Exhaust gas system and combustion air infeed
through the side wall with installation situation 1 or 2
AKD
= Exhaust gas system via the roof (roof cowl kit AKD)
AKW 2
AKD
AKW 2
2
1
1
Dimensions in mm.
Subject to technical changes.