Servicing

Always notify the Truma Service Centre or one of our author-
ised service partners if problems are encountered (see Truma
Service book or www.truma.com).
Attention: Despite careful manufacture, the heating
system may contain sharp-edged components, and pro-
tective gloves should always be worn when carrying out any
maintenance or cleaning work!

Changing battery on the automatic ignitor

If sparking is inaudible, or takes place at intervals of more than
a second, the battery needs replacing.
Replace batteries only if the heater is switched off. Insert a
new battery before the start of the heating season! Dispose of
old battery properly!
Raise the battery compartment cover and replace battery. Pay
attention to plus / minus signs. Close compartment cover.
Only use temperature resistant (+70 °C), leakproof Mignon
batteries (LR 6, AA, AM 3, part no. 30030-99200), other bat-
teries could caus operational faults!
Cleaning (only when the heater is switched
off!)
We recommend removing the dust which has collected on
the heat exchanger, base plate and on the fan wheel of the
Trumavent warm air system at least once a year, before the
heating season starts. Clean the fan wheel carefully using a
brush or toothbrush.

Disposal

Dispose of the unit and the battery in the auto ignitor sepa-
rately as specified in the administrative regulations of the re-
spective country in which it is used. National regulations and
laws (in Germany, for example, the End-of-life Vehicle Regula-
tion) must be observed.
In other countries, the relevant regulations must be observed.

Technical data

determined in accordance with EN 624 or Truma test
conditions
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Rated thermal output
1850 W
Gas consumption
50 – 170 g/h

Manufacturer's terms of warranty

1. Case of warranty
The manufacturer grants a warranty for malfunctions in the
appliance which are based on material or production faults.
In addition to this, the statutory warranty claims against the
seller remain valid.
A claim under warranty shall not pertain
for parts subject to wear and in cases of natural wear and
tear,
as a result of using components in the units that are not
original Truma parts,
for gas pressure regulation systems as a result of damage
by foreign substances (e.g. oils, plasticisers) in the gas,
as a consequence of failure to respect Truma instructions
for installation and use,
as a consequence of improper handling,
as a consequence of improper transport packing.
2. Scope of warranty
The warranty is valid for malfunctions as stated under item 1,
which occur within 24 months after conclusion of the pur-
chase agreement between the seller and the final consumer.
The manufacturers will make good such defects by subse-
quent fulfilment, i.e. at their discretion either by repair or
replacement. In the event of manufacturers providing service
under warranty, the term of the warranty shall not recom-
mence anew with regard to the repaired or replaced parts;
rather, the old warranty period shall continue to run. More ex-
tensive claims, in particular claims for compensatory damages
by purchasers or third parties, shall be excluded. This does not
affect the rules of the product liability law.
The manufacturer shall bear the cost of employing the Truma
customer service for the removal of a malfunction under war-
ranty – in particular transportation costs, travelling expenses,
job and material costs, as long as the service is carried out in
Germany. The warranty does not cover customer service work
in other countries.
Additional costs based on complicated removal and installa-
tion conditions of the appliance (e.g. removal of furniture or
parts of the vehicle body) do not come under warranty.
3. Raising the case of warranty
The manufacturer's address is:
Truma Gerätetechnik GmbH & Co. KG
Wernher-von-Braun-Straße 12
85640 Putzbrunn, Germany
Always notify the Truma Service Centre or one of our author-
ised service partners if problems are encountered (see Truma
Service book or www.truma.com). Please describe you com-
plaint in detail and state the factory number of the device and
the purchase date.
In order for the manufacturer to be able to determine whether
an incident subject to guarantee has occurred, the end user
must, at his own risk, bring or send the device to the manu-
facturer. If there is damage to heat exchangers, the gas pres-
sure regulator must also be sent back to the factory.
Air conditioners:
To avoid transportation damage, the unit may only be sent to
the Truma Service Centre Germany or one of our authorised
service partners if agreed beforehand. Otherwise the sender
bears the risk for any transportation damage.
Please send all shipment to the factory as freight. In cases
under guarantee, the works shall bear the transport costs or
the costs of delivery and return. If the damage is deemed not
to be a warranty case, the manufacturer shall notify the cus-
tomer and shall specify repair costs which shall not be borne
by the manufacturer; in this case, the customer shall also bear
the shipping costs.