10.1.2. Fault: Unit is running but not pumping
1.
No fluid available
• Check fluid level or inlet, if necessary open slide valve
• Clean the supply line, slide valve, suction piece, suction port, or suction strainer
• During standstill, the pressure pipe drains; check the pipework for leakage and the
non-return valve for contaminants; remedy errors
2.
Impeller blocked or impaired movement
• Switch off the unit, secure it against being switched back on again and free the
impeller
3.
Defective piping
• Replace faulty parts
10.1.3. Fault: The unit runs, but not within the specified operating values
1.
Inlet blocked
• Clean the supply line, slide valve, suction piece, suction port, or suction strainer
2.
Impeller blocked or impaired movement
• Switch off the unit, secure it against being switched back on again and free the
impeller
3.
Air in the system
• Vent the system
4.
Defective piping
• Replace faulty parts
5.
Inadmissible levels of gas in the fluid
• Consult the manufacturer
6.
Excessive decrease in the water table during operation
• Check the system's supply and capacity
10.1.4. Fault: The unit does not run smoothly and is noisy
1.
Suction port, suction strainer, and/or impeller clogged
• Clean the suction port, suction strainer, and/or impeller
2.
Impeller stiff
• Switch off the unit, secure it against being switched back on again and free the
impeller
3.
Inadmissible levels of gas in the fluid
• Consult the manufacturer
4.
Signs of wear
• Replace worn parts
5.
Defective motor bearing
• Consult the manufacturer
6.
Unit is installed under tension
• Check installation, use rubber expansion joints if necessary