in the public sewer system is 35 °C and that you must ensure that the water is
cooled accordingly
The noise emission value is less than 70 dB (A).
>
>
As with any electrical appliance, if due to the specific use a failure of the pump
can cause damage (for example in the case of faulty operation, due to a power
failure or a technical defect). If this can result in consequential damage an
alternative system (for example emergency power supply, double pumping
station, network-independent alarm) must be available. In that case, to prevent
uncontrolled water leakage, the FLOW alarm system equipped with float switch
(KBN: FLOWAKS) or FLOW wash machine stop (KBN: FLOWWKS), and for
net-independent operation the NiMH battery 9V block (KBN: ABSBATT9) must be
installed.
ATTENTION!
The lifting unit must not be thrown or dropped during transport or installation. The
lifting unit must not be lifted by the power cable!
>
Observe the correct operating voltage (see "Technical Data").
Never place the power plug in water.
>
>
Connect the lifting unit to a properly installed electrical socket (in compliance
with VDE and the power supply company regulations) protected by at least a 10 A
(slow-blowing) fuse.
>
For submersible pumps of protection classification I, all exposed conductive
parts are connected with a protective earth conductor. Before the unit is put into
operation, an electrically skilled person must check that the protective earth
cable is properly connected.
>
Temperatures higher than those permitted cause the pump to be shut off by the
temperature limiter. After temperature limiter is triggered, disconnect the pump
from the electric system before correcting the cause of the fault, otherwise it will
switch on automatically once cooled down.