5. System Set UP

5
System Set Up

5.1 Dip Switch Functions

Located on the FTC4 printed circuit board are 4 sets of small white switches
known as Dip switches. The Dip switch number is printed on the circuit board
next to the relevant switches. The word ON is printed on the circuit board and on
the Dip switch block itself. To move the switch you will need to use a pin or the
corner of a thin metal ruler or similar.
Dip switch settings are listed below in Table 5...
Make sure to turn off both indoor unit and outdoor unit power supplies before
changing the switch settings.
Dip switch
SW SW- Boiler
SW-2 Heat pump maximum outlet water temperature
SW-3 DHW tank
SW-4 Immersion heater
SW-5 Booster heater
SW-6 Booster heater function
SW-7 Outdoor unit type
SW-8 Wireless remote controller
SW2
SW2- Room thermostat input (IN) logic change
SW2-2 Flow switch input (IN2) logic change
SW2-3 Booster heater capacity restriction
SW2-4 Cooling mode function
Automatic switch to backup heat source operation
SW2-5
(When outdoor unit stops by error)
SW2-6 Mixing tank
SW2-7 2-zone temperature control
SW2-8
SW3
SW3- Room thermostat 2 input (IN6) logic change
SW3-2 Flow switch 2 input (IN3) logic change
SW3-3 Flow switch 3 input (IN7) logic change
SW3-4 Cooling operation in Zone2
SW3-5 Heating mode function *3
SW3-6
SW3-7
SW3-8
SW4 SW4- Multiple outdoor units control
SW4-2 Position of multiple outdoor units control *4
SW4-3
SW4-4
SW4-5 Emergency mode (Heater only operation)
SW4-6 Emergency mode (Boiler operation)
Note:
1. When the hydrobox is connected with a PUHZ-RP/SUHZ-SW outdoor unit of which maximum outlet water temperature is 55ºC, Dip SW1-2 must be
changed to OFF.
2. OUT11 will be available. For safety reasons, this function is not available for certain errors. (In that case, system operation must be stopped and
only the water circulation pump keeps running.)
3 This switch functions only when the hydrobox is connected with a PUHZ-FRP outdoor unit. When another type of outdoor unit is connected, the
heating mode function is active regardless of the fact that this switch is ON or OFF.
4. SW4-2 is available only when SW4-1 is ON.
5. If emergency mode is no longer required, return the switch to OFF position.
2
Function
WITHOUT Boiler
55ºC
WITHOUT DHW tank
WITHOUT Immersion heater
WITHOUT Booster heater
For heating only
Split type
WITHOUT Wireless remote controller WITH Wireless remote controller
Zone operation stop at thermostat
short
Failure detection at short
Inactive
Inactive
Inactive
WITHOUT Mixing tank
Inactive
Zone2 operation stop at thermostat
short
Failure detection at short
Failure detection at short
Not in use
Inactive
Inactive
Slave
Normal
Normal
OFF
WITH Boiler
60ºC
WITH DHW tank
WITH Immersion heater
WITH Booster heater
For heating and DHW
Packaged type
Zone operation stop at thermostat
open
Failure detection at open
Active
Active
Active *2
WITH Mixing tank
Active
-
Zone2 operation stop at thermostat
open
Failure detection at open
Failure detection at open
In use
Active
Active
Master
"Emergency mode (Heater only operation)
(To be activated only when powered ON)"
"Emergency mode (Boiler operation)
(To be activated only when powered ON)"
<Table 5..>
SW4
SW2
SW3
<Figure 5..>
Default settings:
ON
Indoor unit model
OFF
ON *
OFF
OFF
ON
ON
OFF: E*SC-*M*B
ON : EHPX-*M*B
OFF
OFF
ON
OFF: Except
E***-VM2B
ON : E***-VM2B
OFF: Except
ERSC-VM2B
ON : ERSC-VM2B
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF *5
OFF *5