Herunterladen Inhalt Inhalt Diese Seite drucken

Danger Of Fire; Danger To Life; Connecting The Device - Futurelight CL-48 Led-Cluster Bedienungsanleitung

Farbwechsler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and or
damage to property.
The device has to be installed out of the reach of people.
If the device shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The device must never be fixed swinging freely in the room.
Caution: Devices in hanging installations may cause severe injuries when crashing down! If you have
doubts concerning the safety of a possible installation, do NOT install the device!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Mount the device to your trussing system using an appropriate clamp.
For overhead use, always install a safety-rope that can hold at least 12 times
the weight of the fixture. You must only use safety-ropes with quick link with
screw cap. Pull the safety-rope through the attachment eyelet and over the
trussing system or a safe fixation spot. Insert the end in the quick link and
tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety rope which already held the strain of a crash or which is defective
must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the
fixation screws.
Before taking into operation for the first time, the installation has to be approved by an expert!

Connecting the device

On the rear panel of the CL-48 LED-CLUSTER you can find four XLR-jacks (DMX Out) and four XLR-plugs
(DMX In). Connect each DMX OUT-jack with the DMX IN-plug of the next bar.
Additionally, there are four power outputs and four power inputs on the rear panel. Always connect one
output with the input of the next fixture until all fixtures are connected.
Attention: After every 2 CL-48 LED-CLUSTER, the fixtures must have a renewed connection with the power
mains.

DANGER OF FIRE!

DANGER TO LIFE!

23/55
51841355_V_1_0.DOC