Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of Soniccontrol - Kessel EasyClean ground Standard NS 25 Anleitung Für Einbau, Bedienung Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

5.6 Installation of SonicControl

During ground-moving work, a PE-HD cable conduit DN 40
(outer dia. 50 mm) must be laid. For this purpose, the tank must
be scored using a 60 mm hole saw. The connection distance
between separator and control unit must be kept as short as
possible. Unnecessary changes of direction, particularly ones
at angles greater than 45° must be avoided. The cable conduit
must have a continuous gradient to the separator. Condensati-
on inside the cable conduit can be minimised through an airtight
seal on the conduit on the control unit side. A cable pull
Fig. shows Grease Separator EasyClean ground NS 7-35 with SonicControl at the upper section
inside
Fig. shows grommet set SonicControl Art. 917 822
010-223
Installation and assembly
Ensure tight screw
wire can be included for any later cable installation. The cable
can be extended to a max. of 30 m. When the cable is drawn
into the conduit to the control unit, the cable screw connection
at the conduit cover must be tightened firmly.
Then the union nut must be fixed on the end of the pipe.
26/96
Outlet
outside
2019/02

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis