Press the program selection button
program 2. The symbol
LCD. During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars). When the battery is fully
charged, the condition display
The flashing stops and the appliance automati-
cally switches to retention charge.

Program 3

„12 V" (14,4 V / 5,0 A)
For charging 12 V batteries with a capacity of
between 14 Ah–120 Ah.
Press the program selection button
program 3. The symbol
LCD. During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars). When the battery is fully
charged, the condition display
The flashing stops and the appliance automati-
cally switches to retention charge.
Program 4
„12 V" (14,7 V / 5,0 A)
For charging 12 V batteries with a capacity of
between 14 Ah–120 Ah under cold conditions or
for charging AGM batteries.
Press the program selection button
program 4.
NOTE
This program may start with a minute delay.
The symbol
is displayed on the LCD.
During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars). When the battery is
fully charged, the condition display
4 bars. The flashing stops and the appliance
automatically switches to retention charge.

Retention charge

As described under programmes, this appliance
features the automatic retention charge. Depending
on the voltage drop of the battery, caused by
selfdischarge, the appliance reacts with different
charge currents.
The battery can remain connected to the charger
for longer periods of time.
16 
GB │ IE
, to select
is displayed on the
shows 4 bars.
, to select
is displayed on the
shows 4 bars.
, to select
shows

Appliance protection function

The charger switches the electronics off and
switches the system instantly to the basic setting,
as soon as there is an abnormal situation, such as
short circuit, critical voltage drop during charging,
broken circuit or swapped connection of the con-
nector clamps is detected.
Should the appliance become too hot during
charging, the output current is automatically re-
duced. This protects the appliance from damage.

Maintenance and care

WARNING! Before you carry out any
work on the battery charger always pull
the mains plug out of the mains socket.
The appliance is maintenance-free.
Do not under any circumstances use solvents or
other aggressive cleaning agents.
Clean the plastic surfaces of the device with a
dry cloth.
Kompernass Handels GmbH
warranty
Dear Customer,
This appliance has a 3-year warranty valid from
the date of purchase. If this product has any faults,
you, the buyer, have certain statutory rights. Your
statutory rights are not restricted in any way by the
warranty described below.
Warranty conditions
The validity period of the warranty starts from the
date of purchase. Please keep your original receipt
in a safe place. This document will be required as
proof of purchase.
If any material or production fault occurs within
three years of the date of purchase of the product,
we will either repair or replace the product for you
at our discretion. This warranty service is depend-
ent on you presenting the defective appliance and
the proof of purchase (receipt) and a short written
description of the fault and its time of occurrence.
If the defect is covered by the warranty, your product
will either be repaired or replaced by us. The repair
or replacement of a product does not signify the
beginning of a new warranty period.
ULGD 5.0 A1

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis