Fig. 5.1: Final stage (option)
The final stage module is factory mounted.
If required, the final stage module is delivered in a sac.
Mounting the final stage:
1. Dismount the main board
2. Screw the distance bolts with nuts onto the main board
3. Mount the final stage module onto the bolt
4. Bend the flat ribbon cable and solder it onto the main board. Ensure
correct pin assignment on main board and final stage.
5. Put the complete unit back into the housing
6. Use switch S22 to set the signal output to current output (Position 2,
Circle obscured)
7.
Perform balancing only on the main board (P21 and P23,
see chapter 4.1 Zero balance and chapter 4.4 Adjustment).