Herunterladen Inhalt Inhalt Diese Seite drucken

Faults, Causes And Remedies; Spare Parts - Wilo -Plavis 013-C Einbau- Und Betriebsanleitung

Wilo-plavis ...-c series
Vorschau ausblenden Andere Handbücher für Wilo-Plavis 013-C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
• Disassemble the tank and clean it with water or
a  bleac solution
• Check that the probes are not clogged, and clean
them if necessary
• Reassemble the tank
• Perform a function check (chapter 8)
9.2 Checking non-return valve
NOTE: Regularly check that the non-return valve
and the gasket located beneath are not clogged
or blocked.
isassemble t e valve according to g
WARNING! Risk of property damage!
Do not open the non-return valve.
• Check that the non-return valve is not clogged,
and clean it if necessary.
eassemble t e valve according to g
• Perform a function check (chapter 8).

10. Faults, causes and remedies

Faults
The product will not start
The product will not drain
The product starts too often
The alarm is activated

11. Spare parts

Spare parts must be ordered via a local specialist
retailer and/or Wilo Customer Service.
To avoid queries and incorrect orders, all data on
the rating plate should be submitted with each
order.
WILO SE 09/2016
EN
Causes
Power supply cut off
Clogged probes
Damaged power cable
Inlet pipe for condensate is blocked
Drainage pipe blocked
Drainage pipe pinched or damaged
The non-return valve does not open
The non-return valve does not close
ondensate volume o is too ig
The product is tilted too far
The condensate has not been drained
12. Disposal
Your device contains valuable raw materials
which can be recycled. Therefore, please take
your device to your local collection point in your
town or district.
Remedies
Check that the mains plug is correctly
attached to the power supply.
Check the supply voltage.
Clean the probes
Return to customer service
Clean the inlet pipe
Clean the drainage pipe
Reinforce the drainage pipe or replace it
The bending radius of the piping must be
at least 60 mm
Clean the non-return valve
Contact customer service
Check the level
See if the product does not start/does
not drain
Subject to change without prior notice
English
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wilo-plavis 015-cWilo-plavis 011-c

Inhaltsverzeichnis