Example shows the Combi (Gas) device.
1
Verbrennungsluftmotor
2
Umluftmotor
Version of the software in the device < V 05.00.00
The selection of the burner levels depends on the setting of
the connected control panel.
Example
Summer mode is set on the control panel (water temperature
60 °C). Only 2 kW can be selected as a parameter in the
"Burner" field. The output levels 4 kW / 6 kW are not
programmed in the summer mode setting (water temperature
60 °C) in the device's firmware due to the risk of overheating.
End program
1
1 Click the "Burner" field
to change the
parameters of the
burner.
2 Click the "Circulating air
motor" field to change
the parameters of the
circulating air motor.
1 Open the "File" menu
and leave the program
by selecting "Exit".
– Disconnect the
diagnosis cable from the
device tested.
– Switch device off.
"Error Explorer" program – VeGA
Prerequisites for operation:
Device
Version of the software in the device
VeGA
all
Start program
The "Live Display" program must not be active, it must
be closed first if necessary.
1
2
Search for device
1
VeGA ?
1
Display the current action
1 Device search.
2 The error memory is exported.
3 The content of the error memory is prepared for display.
4 Status bar.
5 Device which is connected to the "Diagnose Tool".
1 Start the program by
double-clicking the
"Truma Diagnose Tool"
icon on the desktop.
2 Start "Error Explorer" in
the selection window.
1 Open the "Tools" menu
and click "Start" to start
the search.
5
4
2
3
21