Mover®
Control unit installed in the vehicle
– The control unit of the Mover® must be operational.
– The power supply must be active.
– Connect the 13- or 7-pin plugs of the caravan into the safety
socket.
– Connect the "Diagnose Tool" using the Mover® adapter
cable.
Mover® connection
Mover®
Export error memory
– Start the "Truma Diagnose Tool / Error Explorer" program
on the computer.
Export control unit separately
– Place the control unit on a non-conductive surface.
– Check the wires are connected to the correct terminals.
Operating the control unit without periphery can
generate new errors.
Mover® connection
– Supply control unit with power (12 V DC / min. 0.2 A).
– Simulate the connection of the safety socket with a bridge
(W1).
– Connect the "Diagnose Tool" using the Mover® adapter ca-
ble (W2).
W2
1
2
Interface
Diagnose Tool
Export error memory
– Start the "Truma Diagnose Tool / Error Explorer" program
on the computer.
16
1
2
Interface
Diagnose Tool
W1
12 V
VeGA fuel cell system
Electronics integrated in VeGA
Prerequisites for operation
– The VeGA fuel cell system must be connected and installed
according to the installation instructions.
– Disconnect the digital control panel.
– Connect the "Diagnose Tool" using the adapter cable.
Connection
VeGA
X1 RJ12 coupling for cable extension
Export error memory
– Start the "Truma Diagnose Tool / Error Explorer" program
on the computer.
Export electronics separately
It is not possible to operate the disconnected control unit.
X1
1
2
Interface
Diagnose Tool