"Live Display" program – Combi
Show or change the operating statuses and parameters.
Prerequisites for operation:
Device
Version of the software in the device
Combi (Gas)
> V 03.00.00
Combi D
> V 04.00.00
Mover®

Start program

The "Error Explorer" program must not be active, it must
be closed first if necessary.
1
2

Search for device

1
After a successful search, the operating parameters are
shown in a window. Example shows the Combi (Gas) device.
1
Display the current action
1 Device search.
2 Initialisation of the hardware and software.
3 Communication between the PC and the device.
– Field flashes green – error-free communication.
– Field lit red – interruption.
20
1 Start the program by
double-clicking the
"Truma Diagnose Tool"
icon on the desktop.
2 Start "Live Display" in
the selection window.
1 Open the "Tools" menu
and click "Start" to start
the search.
2
3

Show error detail

Any errors are marked in red on the screen.
Example shows the Combi (Gas) device.
2
1
5
5

Set operating status

Certain operating parameters can be changed on the device
for examinations. Depending on the connected device,
various simulation options can be set.
Simulation options
Circulating air motor *
Burner *
Control panel
Power selector switch
Room temperature sensor
* < V 05.00.00
Version of the soft-
ware in the device
< V 05.00.00
– Connect analogue control panel.
– Set the control knob for the room
temperature to "5".
≥ V 05.00.00
– Disconnect analogue / digital
control panel.
– Set the room temperature to
"25 °C" in the program.
Set the speed of the circulating air motor to at least
25%, otherwise the heater may switch off due to
overheating.
Move the cursor over the required field; the cursor changes
from
(arrow) to
(hand). Click to change the field.
1 Show the error details by
clicking the field marked
in red.
or
2 Show the error details by
clicking the "Error" tab.
4
3 Detailed description of
the error.
4 Return to the "Live
Display" program by
clicking the "Live
Display" tab.
5 For "Combi", μC1, μC2
and μC3 are shown.
3
For "Combi D", only μC1
is shown.
Combi (Gas)
Combi D