Display error list / Combi list of measures

7
1
2
5
4
6
1 Error list
– The current error is marked with (*).
If there is no (*), the current error is undefined.
– Display list of measures by clicking an error.
2 Error description – details about the error (see "Show
details")
3 Flash code
4 One or several measures to rectify the error
5 Group error with "]" – meaning depends on device tested.
Combi – simultaneous occurrence of errors within a data
package.
Mover® – same error occurred several times in sequence.
6 Mover® – a fatal error is additionally marked with (X).
7 Product name of the recognised device e.g. Combi

Show details

Show details of the selected error.
Example shows the Combi (Gas) device.
1
Mehr ...
2

Save error list

The error list can be saved for the communication with Truma.
1
<File name>.tef – .tef = expansion of the file name for the
binary error protocol.
18
3
1 Click the "Tools" menu
and select "More...".
2 Window with details
about the error.
1 Click the "File" menu
and select "Save as...".
– Accept or change
<file name>.
– Click "Save".

Reset errors

The "Reset errors" menu item is only active if the error
list has been stored beforehand in the file system (using
Save error list).
1
Combi (Gas):
Occasionally, the error 65 (Electronics defective) is written into
the error memory during the reset process. If the error was
not previously in the error list, it can be ignored and the error
memory can be reset again.

Reset the Hydronic (diesel burner)

1

Show statistic memory

Prerequisites
– Only Combi (Gas)
Statistics about the device (e.g. operating hours).
1
1 Click the "Product
name" menu and select
"Reset errors".
The error memory in the
device is reset (deleted).
1 Click the "Combi D"
menu and select "Reset
control unit (Hydronic)
error memory".
1 Click the "Product
name" menu and select
"Statistic memory".
2 Statistics about the
device.
2