Herunterladen Inhalt Inhalt Diese Seite drucken

Putting Out Of Operation - Abicor Binzel ABIMIG SpinArc Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
ABIMIG
SpinArc
Shaft position
7 Extend the wire to the required length of the stickout and measure the outer diameter of the wire rotation
using callipers.
After a successful connection, the arc and the rotation of the welding torch are activated using the start
button on the torch guide.
If you do not want rotation to be activated until after the arc has started, use the delay button on the
control device.
Risk of burns
Hot surfaces may cause burns.
• Wait until the torch has cooled down sufficiently before touching it.

8 Putting out of operation

NOTICE
• When putting the system out of operation, ensure that the procedures for switching off each of the
1 Wait until the shielding gas post-flow time has passed.
2 Close the shut-off valve for the gas supply.
3 Switch off the power source.
4 Switch off the control device.
Average rotation diameter in mm
1
2
3
4
5
6
7
8
WARNING
welding system components are observed.
8 Putting out of operation
0.5 – 1.5
1.5 – 2.5
2.5 – 3.5
3.5 – 4.5
4.5 – 5.5
5.5 – 6.5
6.5 – 7.5
7.5 – 8.5
EN - 13