Commissioning/start-up

► Thoroughly clean the pond before starting up the filter system for the first time to ensure that the filter
system is not overloaded by excessively soiled water. OASE recommends using the PondoVac pond
vacuum cleaner for cleaning the pond.
– This cleaning measure is normally not necessary for newly installed ponds.
► It is necessary to operate the filter system for 24 hours a day during the pond season.
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
► Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
► Isolate the device (disconnect from the power supply) before carrying out any work on it.
N O T E
A dimmer or timer will destroy the device.
► Only connect the device to a power supply without dimmer.
► Do not use a timer.
N O T E
Never allow the rinsing pump to run dry. Possible consequences: The rinsing pump will be destroyed.
► Check the water level at regular intervals. Ensure that the rinsing pump is always under water during
operation.
► Do not switch on the control system until the container is flooded with water.
N O T E
During commissioning, Er88 is indicated in the display of the control system,
► for as long as the final water level is not reached in the filter container,
► when the pump status detection is not correctly set.
If the filter system operates correctly, the system message will reset automatically.
6.1

Pump fed system

6.1.1

Order of starting up steps

How to proceed:
 C
1. Close the slide valve for the dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Remove the container cover.
4. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
5. Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing pump).
6. Fit the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted.
7. Switch on the control system and perform any necessary adjustments. (→ Operation)
8. Switch on the filter pump and UVC clarifier (if applicable).
– Ensure that the water is returned to the pond via the return pipe.
9. Check all pipes, hoses and their connections for leaks.
– Expansion seals may leak initially until they have fully expanded on contact with water.
10. Adjust the level detection device, if necessary. (→ Setting the level detection device)