Fitting the unit head

Vitronic 18 W, 24 W, 36 W, 55 W
How to proceed:
 H
1. Check the O-ring on the unit head for correct fit.
– Clean the O-ring, replace it if it is damaged.
2. Carefully push the unit head into the casing up to the stop while applying slight pressure.
– While doing so, slightly turn the unit head to ensure that the tenons and the grooves of the
bayonet closure mesh.
3. Turn the unit head clockwise up to the stop.

Commissioning/start-up

Start-up sequence:
1. Switch on the pump and wait until the casing of the UVC clarifier is filled with water.
2. Switch on the UVC clarifier.
– Never run the UVC clarifier without water flowing through.
3. Check the UVC clarifier function.
4. Check all connections for leaks.

Switching ON/OFF

• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.

Checking the function

 I
Function check
The function display is lit when the UVC lamp is
switched on.
The UV light shines through the transparent
stepped hose adapter when the UVC lamp is
switched on.
The UV light shines through the closing cap
when the UV lamp is switched on.
Vitronic