6.1.2

Setting the level detection device

 S
In the case of pump fed systems, the water level in the filter system is independent of the water level in
the pond. The water level in the filter system is dependent upon the circulation capacity. Therefore it may
be necessary to adjust the level detection device.
The level detection device can be fitted in two positions. This information is based on the assumption that
2 x DN 110 outlets are connected to the last filter module to return the water to the pond.
► Position 1: Suitable for circulation capacities greater than 15000 l/h (factory default setting).
► Position 2: Suitable for circulation capacities smaller than 15000 l/h and fewer automatic cleaning
intervals.
How to proceed:
1. Undo both lock nuts. Remove nuts and Allen screws.
2. Move the level detection device according to the hole pattern and fix in place with Allen screws and
lock nuts. Tighten both nuts.
6.2

Gravity fed system

6.2.1

Order of starting up steps

How to proceed:
 D
1. Close the slide valve for the dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Remove the container cover.
4. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
5. Open the slide valve at the inlet and outlet, if applicable, to fill the filter system with water.
6. Fill the pond until the maximum water level is reached.
7. Check the water level in the Drum Filter Module. Refer to the sticker with level markings on the inside
wall of the container.
– Ideal water level: 100 mm below the top edge of the container
– Permissible tolerance: -20 mm (120 mm below the top edge of the container)
– Correct the installation if the minimum water level is not reached.
8. Check all pipes, hoses and their connections for leaks.
– Expansion seals may leak initially until they have fully expanded on contact with water.
9. Fit the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted.
10. Switch on the control system and perform any necessary adjustments. (→ Operation)
11. Switch on the filter pumps and UVC clarifier in the Individual Module (if applicable).
12. Adjust the level detection device to the water level in the filter system. (→ Setting the level detection
device)
13. Set the filter pump status detection if applicable. (→ Setting the filter pump status detection)
6.2.2
Setting the level detection device
Adjust the level detection device to the water level in the container to ensure the optimum operation of the
filter system. A 10 mm open jaw spanner is required for this adjustment.
How to proceed:
 R
1. Remove the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted and Er11 is indicated in the
display of the control system.
2. Switch off the filter pumps and check the water level.
– Ensure that the water level reaches the height of the maximum mark on the inside wall of the
container, at least above the Min. mark.
– Adjust the water level in the pond if necessary.
3. Switch off the mains voltage (ensure that the control system is isolated).