5

Commissioning/start-up

N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical com-
ponents.
• Do not connect the unit to a dimmable power supply.
Switching on
The pump must be connected to the controller before the controller is switched on.
• First connect the controller to the mains supply, then switch on the pump at the controller.
Switching off
• Switch the pump off at the controller.
– Disconnect the controller from the mains before performing any work on the unit.
When started up, the pump automatically performs a pre-programmed self-test (Environmental Func-
tion Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump switches
off automatically after approx. 90 seconds if it runs dry/is blocked. In the event of a malfunction, dis-
connect the power supply and "flood the pump" or remove the obstacle. Afterwards, the unit can be
restarted.
6

Operation

6.1
Controller overview
Description
1
Four-digit LED display
2
"On/Off" button
3
Arrow keys
4
"Mode" button
5
LED wireless connection
Speed / %
Runtime / h
Power / W
RPM
ON
Error
22
Function
For displaying values
• Standard display is "Power / W" mode.
For switching the pump on or off
For increasing or decreasing rotation speed/power output
• For selecting the next mode
• For switching the wireless connection on/off
• The LED lights up when the wireless connection is
switched on.
• The LED blinks when connected to the OASE App.
The respective LED lights up for the mode that is selected.
• The current mode appears in the display.
The LED lights up when the pump is switched on.
The LED lights up when an error occurs.
• The error code appears in the display. (→ Error messa-
ges)
AMX0087