Functions that are still
available
More than 960 cleaning
• Manual cleaning
Er55
cycles in 48 hours
• Automatic mode
• Time-dependent cleaning
Switch element for rinsing
None
Er66
pump in the control system
overheated
The filter pump is not
Er88
• Manual cleaning
delivering any water or is
• Automatic mode
delivering an insufficient
• Time-dependent cleaning
amount of water.
Possible cause
Remedy
Temporary heavy soiling
Wait until the soiling decreases
• Start-up phase of the filter system
This operating status is atypical. Avoid long-term operation
(e.g. during the first start-up)
in this state.
Fish are spawning
Pond heavily soiled
• Clean the pond
Reduce the amount of soiling
Screen elements heavily soiled
Clean/descale the screen elements (→ Removing/fitting a
screen element)
Insufficient cleaning effect due to soiled
Clean the nozzles
nozzles
Water level in the system too high:
• Clean outlet pipes
• Outlet pipes soiled
• Enlarge outlet opening
• Outlet opening too small
• Reduce flow rate
• Max. flow rate exceeded
Control system is exposed to excessive
Protect the control system from heat
heat (sun, ambient temperature)
Pump status detection incorrectly set
Set the pump status detection. (→ E7: Pump status detection) Automatic after elimination of
The filter pump is switched off.
Switch on the filter pump.
The impeller unit of the filter pump is
Clean the filter pump.
blocked.
- EN -
Resetting the system
message
− Press
key for 5 s
− Automatic if the number
of cleaning procedures
drops below 960.
Automatic when cooled down
the cause