Herunterladen Inhalt Inhalt Diese Seite drucken

Solo Operation; Connecting The Control System With Egc Box; Connecting The Control System - Oase ProfiClear Premium TF-L gepumpt EGC Gebrauchsanleitung

Trommelfiltermodul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
5.3

Solo operation

If no further ProfiClear Premium filter module is connected to the filter module outlets, the height of the
latter needs to be increased. This ensures the required water level in the filter container. The height of the
pipe bend outlet determines the rise level of the water in the filter container. Based on the physical principle
of communicating pipes, the water balances out to the same level in all containers.
OASE provides a suitable discharge set (Order No. 50949). It consists of two pipe bends/DN 110 adapters
with holding plate.
N O T E
To allow connection of the OASE discharge set, it is necessary to change both outlets to DN 110. For this
you need to remove the filter drum. (→ Removing/fitting the filter drum)
Removing the DN 150 outlet
How to proceed:
 K
1. Remove the oval-head screw.
2. Remove the outlet and the sealing ring.
Fitting the discharge set
How to proceed:
 L
1. If not already done: Fit the sealing ring into the wall of the container from the outside.
– Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
2. Fit the outlet adapter to the sealing ring.
– Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
3. Fasten the sealing ring and outlet adapter from the inside with oval head screws.
– Tighten all screws diagonally using the cordless screwdriver to ensure that the sealing ring is
uniformly applied. Further tighten the screws using a Phillips screwdriver.
4. Fit the pipe bend set together in the specified order and fasten to the outlet adapter.
5. Guide the holding plate over the pipe bend and align the pipe elements if necessary.
6. Insert the screws with expansion seals through the holes from the inside. Screw the holding plate from
the outside to the container wall with cap nuts.
5.4

Connecting the control system with EGC box

5.4.1

Connecting the control system

For the pump fed system and for the gravity fed system, the cable harness contains the connection cables
of the signal box, drum motor and rinsing pump. These connection cables have to be connected, the EGC
box is already connected.
 M
► Connect the three connectors of the cable harness to the control system sockets. Hand-tighten the
union nuts.
– The connections are designed to prevent misconnection.
– First flood the container with water, then connect the control system to the mains voltage/power
supply.
54

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Proficlear premium tf-l gravitation egc

Inhaltsverzeichnis