5.3 Dimensions, output values, flue gas values

Registration
External dimensions W x H x D (without lid)
Height with top lids open
Height with top lids closed
Fire box W x D
Fire box height min / max
Hearth plate W x D
Heating door opening W x H
Forward and return connection
Flue gas connection
Water content in heating pocket
Operating pressure max
Waterside pressure loss in heat pocket at a flow of
3
0.85 m
/h:
3
1.7 m
/h:
Required delivery pressure at NHL
Flue gas temperature at flue gas connection at NHL
Flue gas mass flow at NHL wood / brown coal
Room heat capacity with coal for the room with favourable,
less favourable and unfavourable heating conditions ac-
cording to DIN 18893 / Tab. 2.
Operating temperature at regulator setting 1 / 2 / 3
Weight gross / net
CO (13% O
)
2
Dust (13% O
)
2
Efficiency
All information provided by the exhaust gas values are based on the EN 12815 under stationary labo-
ratory conditions reserve the right to make changes which relate to technical advances and / or to an
improvement in quality. We accept no liability for printing errors and changes which occur after printing
Model
Continuous heating
Timed heating
See dimensional drawing 5.4
53
K158 / K158F
CE, 15a B-VG, VKF
234 x 421 mm
270 / 400 mm
442 x 542 mm
173 x 195 mm
each 1" back
150 mm ø
16 l
2.5 bar
3 mbar
13 mbar
12 Pa
210 / 240 °C
31,3 / 39,7 g/sec
3
210 / 120 / 82 m
3
144 / 84 / 58 m
45 / 60 / 80 °C
175 / 164 kg
≤ 0,11 %
≤ 40 mg/m³
≥ 80%