Herunterladen Inhalt Inhalt Diese Seite drucken

System Info - Cameo AURO BEAM 200 DC Bedienungsanleitung

Beam moving head with osram sirius 132 w discharge lam
Inhaltsverzeichnis

Werbung

Test
=
Function test
Reset
=
Reset motors
DEVICE INFORMATION (System Info)
Press MODE to access the selection menu. Using  and , select the menu item "System info" (coloured background) and confirm with ENTER.
System Settings
DMX Address
001
Mode
DMX 16CH
Settings

System Info

This will take you to the sub-menu for displaying device information. Use the arrow keys to select the desired parameter and then retrieve
and/or configure with ENTER.
System Info
Firmware
=
Displays device firmware
Temperature
=
Displays temperature of LED unit
Time Info
=
Displays operating time of spotlight and
operating time of lamp plus reset
Error Info
=
Function error display
If a fault is not corrected by a reset or
restart, the defective unit must be re-
paired by an authorised service centre.
On
Step-by-step function test of the discharge lamp and all motors
(Pan, Tilt, Gobo...)
Off
Stop function test
Pan&Tilt
resets the pan & tilt motors
Head
Resets all head motors (colour wheel, gobo wheel, prism...)
All
Reset all motors
1U01
V1.xx
2U01
V1.xx
3U01
V1.xx
Lamp Temp
xxC / xxF
Temp Unit
Celsius (= display in degrees Celsius)
Fahrenheit (= display in degrees Fahrenheit)
Operating
Displays the operating time of the spotlight in hours
(Xxh)
Lamp
Displays the operating time of the lamp in hours (Xxh)
Lamp Reset
Resets the operating time to zero hours after replace-
ment of the lamp (on -> ENTER)
PAN
Solution: Reset Pan&Tilt
TILT
Solution: Reset Pan&Tilt
Fixgobo
Solution: Reset head
Focus
Solution: Reset head
Prism1
Solution: Reset head
PrismRot1
Solution: Reset head
Prism2
Solution: Reset head
PrismRot2
Solution: Reset head
Frost
Solution: Reset head
Fan1
Automatic shut-off of lamp (blackout)
Display shows: "Lamp Protected"
Solution: Restart the device
Fan2
Automatic shut-off of lamp (blackout)
Display shows: "Lamp Protected"
Solution: Restart the device
Blower
Automatic shut-off of lamp (blackout)
Display shows: "Lamp Protected"
Solution: Restart the device
Temperature
Automatic shut-off of lamp (blackout)
Display shows: "Lamp Protected"
Solution: Wait until normal operating temperature is
achieved (allow to cool). Ignite lamp manually
11