Herunterladen Inhalt Inhalt Diese Seite drucken

Cameo AURO BEAM 200 DC Bedienungsanleitung Seite 14

Beam moving head with osram sirius 132 w discharge lam
Inhaltsverzeichnis

Werbung

Example:
1. Fully disconnect the spotlight from the mains (pull out the plug)!
2. Remove the two screws securing the lamp cover and remove the top cover from the spotlight head.
3. Loosen the four screws of the lamp holder only about one turn.
3
2
4. Loosen the four bolts on the upper head cover and remove the cover.
5. The calibration screw is located to the right of the lamp cover. Turn the calibrating screw clockwise to move the hotspot to the left,
counter-clockwise to move it to the right.
4
5
6. Securely tighten the four screws of the lamp holder and close the lamp cover.
7. Re-install the head cover onto the light head.