Calibration
4
Point the crank arm forward, rotate the rear wheel so the spirit level is horizontal and use the rear brake
to lock the rear wheel in place.
The calibration weight may fall off causing injury if the rear brake is released too quickly or if the calibration pedal bolt is not screwed in
completely.
Be careful to keep hands and feet away from the area below the calibration weight in case it accidently falls.
To increase safety, add a rotational load to the trainer and place the bicycle in the highest gear ratio.
5
In the sensor screen of the SGX-CA900, tap [Pedaling Monitor R] and then [Calibration (Tangential)] in
order.
6
Tap [Start Calibration].
The calibration starts. If the calibration is successful, "Success" appears in [Result]. It may take a up to 1 minute for the
calibration.
If "Failure" appears, the batteries may be dead or the sensors may have malfunctioned. See Troubleshooting (page 47).
7
Slowly loosen the rear brake to release the rear wheel.