Attaching the Sensors

Applying the Adhesive

Apply the adhesive for the sensor to the strain gauge unit.
This work should be done indoors in an ambient temperature of 20 to 35°C.
The adhesive starts to harden after 20 minutes. You must apply the adhesive and finish the bonding process within 20 minutes of
dispensing the adhesive.
Refer to the adhesive's documentation regarding how to use it.
1
Use needle nose pliers to grab the cap, rotate the cap 90 degrees and then pull it off.
When replacing the cap, confirm the position of the marks so you can replace it in the same orientation.
2
Put the tube of adhesive into the caulking gun for the adhesive for the sensors.
Use the caulking gun for the sensor adhesive to squeeze about 3 centimeters of the adhesive onto a rag to make sure it
comes out.
Confirm that the adhesive can be squeezed out, attach the mixing nozzle, and then dispose of the rags.
3
Squeeze about 3 centimeters of the adhesive onto the palette.
After dispensing the adhesive, immediately remove the mixing nozzle, and replace the cap of the adhesive in its original
orientation.