Point the crank arm down and adjust the angle so the level indicates it is perpendicular.
9
In the sensor screen of the SGX-CA900, tap [Pedaling Monitor R] and then [Calibration (Radial)] in order.
10
Tap [Start Calibration].
The calibration starts. If the calibration is successful, "Success" appears in [Result]. It may take a up to 1 minute for the
calibration.
If "Failure" appears, the batteries may be dead or the sensors may have malfunctioned. See Troubleshooting (page 47).
11
Carefully remove the calibration weight, the calibration pedal bolt and the spirit level.
This completes the calibration with a load on the pedals.
Next, calibrate the zero point.
EN
Calibration