Calibrating the sensors (zero point calibration)

This section describes how to use the Cyclocomputer to calibrate the zero
point of the pedaling monitor sensor that is installed on the bicycle. Zero point
calibration is a function to store the zero point (no-load), where no forces act
on the crank, in the sensor memory.
• Zero point calibration should be done by customers whenever the measurement value is
deviating.
• Please do not push the push switch in the right transmitter while calibrating the sensor
with the Cyclocomputer.
Calibration method in pedaling monitor mode using SGX-CA600

Getting Started

1. Stop the bicycle on a flat
safe place.

Calibrating the Zero Point

1. Position the crank arm so
it is perpendicular to the
ground, pointing downward.
2. Select [Calibration] in the
main menu of SGX-CA600.
The calibration (zero) screen appears.
3. Select [LR Zero Calibration].
The calibration starts.
If the calibration is successful,
"Success" appears.
If "Failure" is displayed, the sensor may
be calibrated in an unstable condition
causing the crank to be moving during
the calibration. Calibrate again with the
crank in a stable position.