Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Of Pneumatic Power Supply; Connecting The Direct Print Module - Carl Valentin Dynacode II 107 Kurzanleitung Und Hinweise Zur Produktsicherheit

Und hinweise zur produktsicherheit
Vorschau ausblenden Andere Handbücher für Dynacode II 107:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Dynacode II

Connection of Pneumatic Power Supply

The pneumatic power supply for the printhead mechanics has to be made available a minimum continuous pressure of 4 - 6
bars in front of the pressure regulator. The maximum pressure in front of the pressure regulator is 7 bars and 4 bars after the
pressure regulator.
NOTICE!
A pneumatic power supply of 4 bars is recommended.
Please observe the following notes:
The compressed-air has to be dry and oil free.
The supplied pressure regulator with manometer is to connect with a plastic tube Ø 8 mm via a plugging bolting to the
pneumatic power supply. It is necessary to make a connection between the pressure regulator and the print mechanics via
a plastic tube Ø 8 mm.
Position pressure regulator as near as possible to the print mechanics.
The pressure regulator is only to operate in the direction that is indicated on its underside. The direction shows the way of
the streaming air.
It is not allowed to bend the plastic tubes.
Shortening of the plastic tubes has to be made with a clean right-angled cut without squashing the tube. If necessary use
special tools (available in pneumatic requirements).
Please observe a possible short length of the 8 mm plastic tubes.
Druckmechanik
Print mechanics
Druckregler mit Manometer
Pressure regulator with manometer

Connecting the Direct Print Module

The direct print module is equipped with a versatile power supply unit. The device may be operated with a mains voltage of
110-230 V / 50-60 Hz without any adjustments or modifications.
CAUTION!
The direct print module can be damaged by undefined switch-on currents.
Set de power switch to '0' before plugging in the direct print module.
Insert power cable into power connection socket.
Insert plug of power cable into a grounded electrical outlet.
NOTICE!
Insufficient or missing grounding can cause faults during operation.
Ensure that all computers and connection cables connected to the direct print module are grounded.
Connect direct print module to computer or network with a suitable cable.
68
Pneumatikschlauch
Pneumatic tube 8x1
Druckluftversorgung
Pneumatic power supply
min. 4 bar, max. 7 bar
English

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dynacode ii 53Dynacode ii 128

Inhaltsverzeichnis