AVENTICS | IS12-PD | R422003649–BAL–001–AB | English
11 Removing the Valve from the System
Danger of injury if valve disassembled under pressure or voltage!
Uncontrolled movement of the system components!
O Make sure that the system is not under pressure or voltage when you
disassemble the valve, coil, electrical connector, or the M8x1 socket.
Contamination during disassembly!
During disassembly, greases or lubricant may escape from the valve.
O Make sure that the environment is not contaminated with greases or lubricant
during disassembly.
1. Stop system operation and protect it against being switched on.
2. Ensure that the useful load has reached a stable position.
3. Make sure that the relevant section of the system is not under pressure and
protect it against being switched on.
4. Remove the electrical connector from the coil.
5. Remove the sensor plug from the controller.
6. Loosen the four mounting screws on the valve and remove the valve from the
base plate.
This concludes the disassembly.
12 Exchanging the Coil
To operate the valve with a different voltage, for example, you can exchange the coil.
1. Proceed as described in steps 1.–4. of chapter "11 Removing the Valve from the
System".
2. Proceed as described in section "Assembling the coil" in chapter 7.
3. Proceed as described in section "Connecting the coil" in chapter 7.
13 Disposal
O Dispose of the valve and any escaping greases and lubricant in accordance with
the national regulations in your country.
WARNING
NOTICE

14 If Malfunctions Occur

Danger of injury by dismantling the IS12-PD valve!
Pre-tensioned springs may suddenly be released when dismantling the valve.
O Never dismantle the valve.
O Do not attempt to perform any unauthorized repairs.
O Check the connections, operating voltage, and working pressure of the relevant
system part if malfunctions occur.
Additional help for malfunctions can be found in the following table:
Malfunction
Possible cause
Valve does not
Insufficient control
switch
pressure.
Valve is not leaktight at
all.
Incorrect pin assignment
of the electrical
connector
Insufficient voltage
Sensor LED not
Incorrect M8x1 socket
illuminated
pin assignment
Insufficient voltage
Excessive voltage
If you are unable to troubleshoot the valve malfunction yourself:
O Disassemble the valve as described in chapter "11 Removing the Valve from the
System" and send the valve to AVENTICS GmbH. You can find the address on the
back of the operating instructions.
WARNING
Remedy
Increase the control pressure.
Disassemble it and send it,
together with a description of the
error, to AVENTICS GmbH.
Check and correct the pin
assignment of the electrical
connector.
Use pre-assembled connecting
cables with electrical
connectors.
Increase voltage to the minimum
voltage value.
Check and correct the pin
assignment
Use pre-assembled connecting
cables.
Increase voltage to the minimum
voltage value.
Exchange valve