2nd - Second level of Set-up Menu
The functions PPU (Push-Pull Unit), C-C (Cooling-unit cut-out),
are located in a second menu level.
Changing to the second menu level (2nd)
- Choose the parameter "2nd", as described in the sections
headed "Acessing the setup-menu"
- Press and hold the MEM button
- Press the Process button
- Release the MEM button
The power source is now in the second menu level (2nd) of the
set-up menu. The function "PPU" (Push-Pull Unit) is now
displayed.
Select function
- Select the required function with the Process button
- Set up the function as described in the following sections
Exit from the second menu level (2nd)
- Press the MEM button
N.B! Any changes only become active if you switch to a
different function or exit from the second menu level (2nd).
PPU... Push-Pull Unit (see the section headed "Push-Pull
Unit")
C-C ... Cooling unit cut-out ... ON / OFF / Aut
Factory setting: Aut (automatic)
PushPull Unit
The PushPull unit must be adjusted prior to each initial start-up.
In case no adjustment is made the standard parameters will be
used - which may result in that the weld result is not satisfac-
tory.
- Select the function „PPU" in the second menu level (2nd).
P P U
- Use the adjusting dial
unit from the following list
5 ....... Hand PushPull with power potentiometer
6 ....... Hand PushPull without power potentiometer
7 ....... Binzel Hand PushPull 42V with power potentiometer
8
Binzel Hand PushPull 42V without power potentio-
meter
9 ....... Binzel Robot PushPull 42V (gear ratio: 17,1:1)
10 .... Binzel Robot PushPull 24V (gear ratio: 17,1:1)
11 .... Dinse Robot PushPull 42V
12 .... Hulftegger Hand PushPull
1)
Motor and gear tolerance may cause functional variation
- possibly adjustment at the factory required.
5
to select the respective PushPull
P P U
- Press torch key
S T I
- Uncouple drive units of both wire feed motors (e.g. welding
torch and wire feeder) - wire feed motors must be unloaded
- Press torch key
The wire feed motors are adjusted when in unloaded
condition; in the meantime the right-hand display will read
„run".
S T I
- As soon as the adjustment in unloaded condition is comple-
te, the display will read „St2"
S T 2
- Uncouple drive units of both wire feed motors
- Feed in the welding wire in the drive units of both wire feed
(e.g. welding torch and wire feeder)
Caution! Hold welding torch such that it is directed away
from the body - hazard from welding wire coming out.
- Press torch key
Wire feed motors are adjusted when in loaded condition; in
the meantime the right-hand display reads „run"
S T 2
- Adjustment of the PushPull unit is successfully completed if
the displays read „PPU" and the value adjusted, e.g. „5"
P P U
- Press the MEM button
1)
1)
48
6
6
twice to exit the Setup menu