7.3. Restoring the original configuration

This reset deletes all control points, all the sensors and all the end limit settings, and resets the
motor's direction of rotation and favourite position (my).
The upper end limit is cleared.
The favourite position of the actuator is reset to 600 ms from the lower end limit position.
The direction of rotation of the actuator is that specified in section 5.
Do not place the blind, in the Upper end limit !
• Cut the power supply for 2 seconds.
• Next:
Switch the power supply back on for 5 to 15
seconds.
A
Cut the power supply for 2 seconds.
Switch the power supply back on: the E.V.B.
starts to move for a few seconds.
• or
Switch the mains power supply back on.
Wait for 5s then press·and·hold·the·»mushroo
B
m»·for·10·seconds.
the E.V.B. moves briefly.
If the E.V.B. is at the upper or lower end limit, it will
move briefly.
• Hold down the PROG button: the E.V.B. will move
once then again a few moments later. The motor
is configured with the factory settings.
The current position of the blind becomes the
new lower end limit position.
Repeat the procedures from the «Commissioning»
section

8. TECHNICAL DATA

Radio frequency
Power supply
Operating temperature
Index protection rating
Maximum number of connected control points
Maximum number of connected sensors
Safety level
Torque (Nm)
Motor length (mm)
Acoustic power level
86
A
5 sec.
ON
OFF
15 sec.
ON
433.42 MHz
230 V ~ 50 Hz
- 20 °C à + 60 °C
IP 54
12
3
Classe I
6
10
254
269