Display menus

Monitor
Function monitoring
Values can not be changed within these menus!
in Proc.
Process
XXXXXXXX
XXXXXXXX:
Init!
Error?
Driving?
Stop?
Tv1
Tv2
Ramp
Ignition
Tv3
Tv4
The control logic processes the signals in this order.
BreakCon
Brake interrupt
XXXXXXXX
XXXXXXXX
None
TimeOut Set braking time ended
Man.Stop Braking process interrupted by opening the start contact
Aut.Stop Standstill detected automatically (operation with automatic
Int.Temp Permitted heatsink temperature exceeded
Ext.Temp Permitted (external) motor temperature exceeded
Overload Permitted braking current exceeded
OvLd-tv1 Permitted braking current exceeded during t
OvLd-tv2 Permitted braking current exceeded during t
OvLd-Rmp Permitted braking current exceeded during the run-up ramp
OvLd-Ign Permitted braking current exceeded during the braking process
Watchdog Internal error
PKB-M, PKB-MS Operating Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DETECTION ET AUTOMATISME - 17 Rocade de la Croix St Georges - 77600 BUSSY ST GEORGES - Tél : 01.64.66.90.00 - Fax : 01.64.66.98.01 - mail : infos@dplusa.fr
Initialisation
Temperature test
Waiting for the start contact to open (motor on)
Waiting for the start contact to close (motor off)
Safety time t
v1
Safety time t
v2
Run-up of the current control
Braking operation with set current set value (control) or firing
time point (without control)
Safety time t
v3
Safety time t
v4
No brake interrupt (e.g. by switching on the unit)
standstill detection)
time
v1
v2
15