Safety

Safety regulations

• The unit may only be installed and commissioned by a competent,
• Transport, storage and operating conditions in accordance with
• When the unit has reached the end of its lifecycle, dispose of it carefully
• Install the unit in a control cabinet with protection type IP 54
• Keep the slots in the housing free so the unit is sufficiently ventilated
• The unit may only be connected as shown in the diagrams in the section
• If you are using the unit to replace the P4B 3NK brake unit, please note
• No harmful emissions are produced should the unit catch fire or burn.

Intended application

The mini braking unit provides a controlled, soft braking of 3-phase
asynchronous motors and has been designed specifically for this purpose.
The use of this unit for any other purpose is seen as an improper
application.
The device is designed for use in industrial environments only. It is not
suitable for use in a domestic environment as this can lead to
interferences.
All claims to warranty and liability will be rendered invalid if
• The unit was used contrary to the purpose for which it was intended
• Damage can be attributed to not having followed the guidelines in the
• The housing was opened,
• Any components were changed or any technical or electrical
2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DETECTION ET AUTOMATISME - 17 Rocade de la Croix St Georges - 77600 BUSSY ST GEORGES - Tél : 01.64.66.90.00 - Fax : 01.64.66.98.01 - mail : infos@dplusa.fr
qualified electrician who is familiar with this operating manual and the
basic regulations concerning health and safety/accident prevention.
Follow all VDE and local regulations, inparticular those regarding
preventive measures as well as fire prevention regulations
EN 60068-2-6, 04/95 (see Technical Data)
and according to any relevant environmental regulations
"Commissioning" on page 6
that the connections on the two units are not compatible. When
connecting the unit you must refer to the table under "Commissioning",
otherwise the unit may be destroyed.
manual
modifications were carried out.