Operation
IB XX.XA
Firing time point default
o YYYYY#
XX.X
YYYYY
Relative firing time point relates to the zero voltage switching with a
resolution of 333 ns. If the firing time point increases, the braking current
increases. The parameter is used for setting the braking current when the
control is switched off.
WARNING!
When the control is switched off the permitted braking current could be
exceeded. Always keep a check on the braking current display and, if
necessary, reduce the size of the firing angle.
Example: With a test braking (set "Auto") the firing angle is given via the
control and appears in the menu. If you switch off the control now
(Proportional factor "off" ), then you can increase or decrease the value
given and therefore, influence the size of the firing angle.
Inter-
Interface
face
Intface
Interface type
XXXXXXXX
XXXXXXXX Off: off
Baudrate
Bit rate for transmission
XXX00/s
XXX00
Address
Bus address
XXX
AXXX
12
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DETECTION ET AUTOMATISME - 17 Rocade de la Croix St Georges - 77600 BUSSY ST GEORGES - Tél : 01.64.66.90.00 - Fax : 01.64.66.98.01 - mail : infos@dplusa.fr
Current braking current in amps
Firing time point (firing angle)
Auto: The firing time point is determined by the following
braking process
Slave Br: Operation with Slave brake
ser.Asyn: MODBUS-operation
Bit rate for MODBUS operation (300, 600, 1200, 2400, 4800,
9600, 19200 und 38400 Bit/s)
Bus address for MODBUS-operation
PKB-M, PKB-MS Operating Manual