www.dplusa.fr
Stand-
Standstill
still
Only on the version with automatic standstill detection
Br.Mode
Braking mode
XXXX
XXXX
The following four parameters determine standstill detection. The control
logic covers 4 steps (1 to 4), where one step must always be complated
before the next step can begin: (1) start-up suppression time, (2) level 1
exceeded, (3) falls below level 2 and (4) braking current overrun.
The signal cycle can be seen on the standstill display.
deadtime
Start-up suppression time (deadtime)
XX.Xs
XX.X
Level1
Switch-on braking threshold
XXX#
XXX
Level2
Switch-off braking threshold
XXX#
xxx
OffDelay
Braking current overrun
XX.Xs
XX.X
PKB-M, PKB-MS Operating Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DETECTION ET AUTOMATISME - 17 Rocade de la Croix St Georges - 77600 BUSSY ST GEORGES - Tél : 01.64.66.90.00 - Fax : 01.64.66.98.01 - mail : infos@dplusa.fr
Time: brake until preset time
Auto: brake until standstill
"Adjust time" in seconds; used also to suppress the settling
effects at the start of braking. Standstill detection during this
time is not possible.
Mid-value can be set between the highest and second highest
signal level: also used to switch off fault pulses
Value can be set below the switch-on threshold; determines the
beginning of the braking current overrun.
Time in seconds between the detected standstill and the actual
end of the braking process, i.e. braking current switched off.
13