6.2. DC Voltage Measurement
1.
Connect the black test lead to the COM jack and the red test lead
to the V/Ω/ mA- jack.
2.
Set the function switch to the DC V range to be used and
connect the test leads across the source or load under
measurement.
Note:
1.
If the voltage range is not known beforehand set the function
switch to the highest range and work down.
2.
When only the figure "OL" is displayed, overrange is being
indicated and the Function switch must be set to a higher range.
3.
CAUTION: Do not apply more than 600 V to the input. Indication is
possible at higher voltages but there is danger of damaging the
internal circuitry.
4.
Use extreme caution to avoid contact with high tension circuits
when measuring high voltage.