Herunterladen Inhalt Inhalt Diese Seite drucken

Alarm Management - Palazzetti easytouch Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

11 ALARM MANAGEMENT

If a malfunction occurs, the following procedure is activated:
1. audible alarm (beep);
2. one of the following system LEDs come on:
3. if the problem concerns an error, the stove will switch off.
Pressing and holding the "cancel" button
ERROR/
WARNING CODE
E001
E002
E004
E101
E105
E106
E108*
E108**
E109*
E109**
E110
E111
A001
A002
A007
----
----
After having checked the type of message, the alarm can be reset by pressing the on/off
button
for a few moments.
52/13
USE AND & MAINTENANCE
DESCRIPTION
Faulty control panel
Remote control signal communication error Control panel fault
Communication error
Failed ignition error
Outlet water temperature too high
Temperature probe malfunction
Temperature probe malfunction
Safety error
Thermal safety
Incorrect pressure or thermal cutout
Pressure error
Temperature probe malfunction
Flue gas temperature probe malfunction
Low pellet level
Scheduled maintenance warning
Pressure sensor malfunction
Clean stove
Failed ignition error
Then the stove can be started again.
cod. 004772532 - 07/2018 - Palazzetti - PN - Italy
;
shows the error code on the display:
POSSIBLE CAUSES
Control panel fault
Connection cable between board and control panel
interrupted or detached.
error
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
Faulty return water temperature probe
Faulty buffer tank temperature probe
Door or loading hatch open
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
Flue system dirty
Seals worn
Heating system malfunction
Circulation pump malfunction
Pellet tank overheating
Flue gas exhaust system dirty
Seal gaskets worn
Faulty outlet water temperature probe
Faulty air temperature probe
Pellets running out
The stove periodically requires maintenance to be
Pressure sensor or board fault.
dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets; Faulty ignition heater; Worn gaskets; Incorrect
burn pot position
LED
Fig.11.1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ecofire idro

Inhaltsverzeichnis