Operating Instruction
5.3 Manually modifying the ID
EN
Please note:
The duplication and program-
ming function only works with the
Herth+Buss wheel sensor.
Other sensors cannot be written.
Function selection:
Use the arrow buttons to select MANUAL ID
MODIFYandpresstheenterkeytoselect.
Checking the original ID:
Place the target sensor close to the AirGuard
andpresstheenterkeytoscantheoriginal
IDnumber.Thisensuresthatthisisthecor-
recttargetsensorthatyouwishtomodify.
www.herthundbuss.com
Scan complete:
TheAirGuardwillnowshowthetargetsen-
sor ID. You will hear two short beeps after the
sensor has been scanned. Press the enter
keytorecord.
Enter the sensor ID:
Usethearrowbuttonstonavigate.Pressthe
enterkeytoentertheIDdigits.
Modification complete:
The AirGuard will now modify the target
sensorforyou. Y ouwillheartwoshortbeeps
afterthesensorhasbeensuccessfullymodi-
fied.
95990001