Herunterladen Inhalt Inhalt Diese Seite drucken

Putting Into Operation - Abicor Binzel ABIMIG GRIP W Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ABIMIG GRIP W:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
ABIMIG
GRIP W

3 Putting into operation

3.1 Equipping the torch
®
ABIMIG
GRIP W
W 555 D
W 555
W 605
W 605 D
W 605 C
1
Gas nozzle
2
Gas nozzle adapter
3
Gas diffuser
Fig. 1
Equipping the torch
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply and cut off the gas supply.
• Pull the mains plug.
CAUTION
Risk of injury
Through-hole or puncture caused by electrode tip.
• Do not reach into the danger zone and wear protective gloves.
NOTE
• Order data and part numbers for the equipment parts, wear parts and
accessories can be found in the current ABICOR BINZEL spare parts
and wear parts lists.
• Use only original ABICOR BINZEL wear parts.
• Use a multiple wrench to fasten the wear parts.
Equip the torch necks according to the following figure. Observe the correct
assignment and tight fit of the wear parts:
1
2
4
Contact tip
5
Tip adaptor
6
Collet chuck
3
4
5
7
Torch neck
8
Multiple wrench
3 Putting into operation
6
7
8
EN - 5

Werbung

Inhaltsverzeichnis
loading