5 Operation
4.1 2-cycle function of the trigger
5 Operation

6 Putting out of operation

7 Maintenance and cleaning

EN - 8
1 Press the trigger on the handle and keep it pressed = welding is started.
2 Release the trigger = welding is stopped.
1 Open the shielding gas cylinder.
2 Switch on the power supply.
3 Set the welding parameters.
4 Start welding.
NOTE
• Liquid-cooled cable assemblies start leaking when overheated. This is
why the cooling unit should continue running for approx. 5 min. after
welding.
1 Stop welding.
2 Wait until the shielding gas flow has subsided and then switch off the power
supply.
3 Close the valve of the shielding gas cylinder.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, installation, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply and close off the gas supply.
• Pull the mains plug.
®
ABIMIG