3.4 Setting the shielding gas quantity
3.5 Feed in wire

4 Operating elements

NOTE
• Check the minimum coolant level of the cooling unit.
• Coolant supply = blue, coolant return = red.
• Make sure that liquid-cooled MIG/MAG welding torches are only
operated with the ABICOR BINZEL coolant BTC-15.
• Each time the device is commissioned or after each cable assembly
change, the cooling system must be purged of any air. Disconnect the
coolant return hose from the re-circulating cooling unit and hold it over a
collecting device. Close opening at the coolant return. Open it again by
repeatedly and abruptly releasing it, until the coolant is flowing
continuously and without air bubbles.
NOTE
• The type and quantity of the shielding gas depends on the welding task
and the gas nozzle geometry.
• Make all shielding gas connections gas-tight.
• To prevent the shielding gas supply from becoming clogged by
impurities, the cylinder valve must be opened briefly, before connecting
the cylinder. This will blow out any impurities that may be present.
1 Insert the wire in the wire feeder as specified by the manufacturer.
2 Press the "Current-less wire feed" push-button at the wire feed unit until the
wire emerges from the contact tip.
NOTE
®
• As the ABIMIG
GRIP W welding torches are integrated into a welding
system, the operating instructions of the welding components, such as the
welding power supply, must be observed during operation.
Using a standard welding torch, the two-cycle mode of the trigger can be
activated. Further operating modes and handle modules depend on the
corresponding welding power supply and must be ordered separately.