3. Ope ra ti on

3.6 En gine hour in di ca tor

The en gine hour in di ca tor (1) can be used to call up var i ous in -
for ma tion:
-
En gine oil and air fil ter re place ment in ter vals are shown:
1. Serv.-
alarm
CHG
Dis play
OIL
In ter val
20 hours
Count
down
Blin king time 2 hours
Op er at ing hours in whole hours.
1)
Op ti on
1)
2. Serv.-
3. Serv.-
4. Serv.-
alarm
alarm
alarm
CHG
Serv
CHG
OIL
Air Fil ter
Air Fil ter
200 hours
50 hours
250 hours
15 hours
25 hours
be fo re
be fo re
1)
3.7 Wa ter spray
Fill the wa ter tank only with wa ter or an ti freeze mix ture.
If there is dan ger of freez ing, empty the wa ter sprin kler
or fill it with an ti freeze mix ture.
Fill the wa ter tank (2) through the tank open ing (1).
Use the rod (3) to turn the pipe 90°:
-
Po si tion «0» = Wa ter spray off
-
Po si tion «I» = Wa ter spray on