Replacing the Swivel for Disc
Cooling
Suggestion 1
Alternative Suggestion 2
RotoPol-31/-35
Instruction Manual
Only relevant when disc cooling is being used:
Struers recommends that the swivel be replaced at least every
two years.
Turn off the power and remove the plug and the cable before
opening the machine. Place RotoPol-31/-35 as indicated in
suggestion 1 or 2:
Place RotoPol-31/-35 on two tables with the rubber feet resting on
the tables as shown in the sketch, so as to have access to the
underside of RotoPol-31/-35.
Swivel.
Bottom plate.
Remove the specimen mover, if mounted, and carefully tilt
RotoPol-31/-35 to one side so as to have access to the base.
Remove the protection guard for the swivel.
Remove the tube on the swivel: push the ring and pull off the
tube. Pull the tube out of the clips.
Remove the bottom cover.
Support the belt wheel and unscrew the swivel with an open-
end spanner.
Fasten the new swivel with a moderate torque and mount the
parts again.