Verfügbare Sprachen

12.2

Replacing the operator

12.2.1 Disassembling the operator

1
2
3
Unscrew the hexagon screw 1.
G
Do not lose the washer 2.
G
Unscrew screw 3.
G
The operator 4 can now be removed
G
from the ball valve body.

12.2.2 Mounting the operator

1
2
3
762
Place the new operator 4 on the ball
G
valve body.
Turn the operator until the hexagon
G
screw 1 and screw 3 can be inserted.
Tighten the operator with screw 3.
G
Screw in hexagon screw 1 with washer 2
G
hand tight.
12.3
4
Use of wrong spare parts!
Damage to the ball valve!
®
Manufacturer liability and guarantee
®
will be void.
Only the listed spare parts may be
G
replaced.
Only use genuine GEMÜ spare parts!
G
When ordering spare parts, specify
G
the complete order number of the ball
valve.
Disassemble the operator (see chapter
G
12.2.1 "Disassembling the operator").
4
Bend downwards the lug of the screw
G
locking device 13.
28 / 36