INSIDE
Assembly
10
13
10.
Connect magnetic valve.
11.
Connect sensor siphon.
12.
Attach ceramics. ATTENTION! Don't clamp calbes.
Restore water and power supply.
13.
Perform function test (flush with min. 1 liter of water).
14.
Establish waterproof silicon pointing around the ceramics.
11
14
12
Following steps must
be done in order as
described necessarily!
Urinal control WimTec INSIDE
EN
!
ATTENTION!
27